Slider 60

ID: 1112_1

Ideal for user input, this slider has 60mm of travel and connects to an Analog Input or VINT Hub port.

Replaced by POT2001_0

Replaced by the POT2001_0, which has the same mounting dimensions and travel length as the 1112.



The Slider 60 is a linear potentiometer - the resistance varies linearly with the position of the slider. It outputs a voltage ratio between 0 and 1 that varies linearly over the 60mm of travel. The maximum resistance is 10K ohms.

The 1112 can be used as human input or as position feedback in a system.


Comes packaged with

Functional

Interface Boards and Hubs

This sensor can be read by any Phidget with an Analog Input or VINT Hub port. It will connect to either one using the included Phidget cable. VINT Hub ports can behave just like Analog Inputs, but have the added flexibility of being able to be used as digital inputs, digital outputs, or ports to communicate with VINT devices. For more information about VINT, see the VINT Overview page.

Product Voltage Inputs
Part Number Price Number of Voltage Inputs Voltage Input Resolution (bits)
1010_0
PhidgetInterfaceKit 8/8/8 Mini-Format
$80.00 8 10 bit
1011_0
PhidgetInterfaceKit 2/2/2
$50.00 2 10 bit
1018_2B
PhidgetInterfaceKit 8/8/8
$80.00 8 10 bit
1018_3B
PhidgetInterfaceKit 8/8/8
$80.00 8
1019_1B
PhidgetInterfaceKit 8/8/8 w/6 Port Hub
$110.00 8 10 bit
1203_2B
PhidgetTextLCD 20X2 : White : Integrated PhidgetInterfaceKit 8/8/8
$70.00 8 10 bit
DAQ1000_0
8x Voltage Input Phidget
$20.00 8 12 bit
HUB0000_1
VINT Hub Phidget
$30.00 6 (Shared) *** 15 bit
HUB0001_0
VINT Hub Phidget
$35.00 6 (Shared) * 15 bit
HUB0002_0
VINT Hub Phidget
$40.00 6 (Shared) *** 15 bit
HUB0007_0
1-Port VINT Hub Phidget
$24.00 1 (Shared) ** 16 bit
HUB5000_0
Wireless VINT Hub
$60.00 6 (Shared) * 16 bit
SBC3003_0
PhidgetSBC4
$120.00 6 (Shared) * 16 bit

Phidget Cables

This sensor comes with its own Phidget cable to connect it to an InterfaceKit or Hub, but if you need extras we have a full list down below. You can solder multiple cables together in order to make even longer Phidget cables, but you should be aware of the effects of having long wires in your system.

Product Physical Properties
Part Number Price Cable Length
3002_0
Phidget Cable 60cm
$2.00 600 mm
3003_0
Phidget Cable 10cm
$1.50 100 mm
3004_0
Phidget Cable 350cm
$3.00 3.5 m
3038_0
Phidget Cable 120cm
$2.25 1.2 m
3039_0
Phidget Cable 180cm
$2.75 1.8 m
CBL4104_0
Phidget Cable 30cm
$1.75 300 mm
CBL4105_0
Phidget Cable 90cm
$2.00 900 mm
CBL4106_0
Phidget Cable 150cm
$2.50 1.5 m
KIT4030_0
Phidget Cable Kit
$10.00 80 mm


Getting Started

Welcome to the 1112 user guide! In order to get started, make sure you have the following hardware on hand:


Next, you will need to connect the pieces:

1112 1 Connecting The Hardware.jpg
  1. Connect the 1112 to the HUB0000 with the Phidget cable.
  2. Connect the HUB0000 to your computer with the USB cable.


Now that you have everything together, let's start using the 1112!

Using the 1112

Phidget Control Panel

In order to demonstrate the functionality of the 1112, we will connect it to the HUB0000, and then run an example using the Phidget Control Panel on a Windows machine.


The Phidget Control Panel is available for use on both macOS and Windows machines. If you would like to follow along, first take a look at the getting started guide for your operating system:


Linux users can follow the getting started with Linux guide and continue reading here for more information about the 1112.

First Look

After plugging in the 1112 into the HUB0000, and the HUB0000 into your computer, open the Phidget Control Panel. You will see something like this:

HUB0000 Panel.jpg


The Phidget Control Panel will list all connected Phidgets and associated objects, as well as the following information:

  • Serial number: allows you to differentiate between similar Phidgets.
  • Channel: allows you to differentiate between similar objects on a Phidget.
  • Version number: corresponds to the firmware version your Phidget is running. If your Phidget is listed in red, your firmware is out of date. Update the firmware by double-clicking the entry.


The Phidget Control Panel can also be used to test your device. Double-clicking on an object will open an example.

Voltage Ratio Input

Double-click on a Voltage Ratio Input object in order to run the example:

1018 Sensors VoltageRatioInput.png


General information about the selected object will be displayed at the top of the window. You can also experiment with the following functionality:

  • Modify the change trigger and/or data interval value by dragging the sliders. For more information on these settings, see the data interval/change trigger page.
  • Select the 1112 from the Sensor Type drop-down menu. The Sensor Value will now return a value between 0 and 1. The slider will report 0 at one end and 1 at the other end, making it ideal for use as a human input or position feedback device in a system.


Technical Details

General

The maximum resistance of the slider is 10kΩ.

Phidget Cable

Analoginput.jpg

The Phidget Cable is a 3-pin, 0.100 inch pitch locking connector. Pictured here is a plug with the connections labelled. The connectors are commonly available - refer to the Analog Input Primer for manufacturer part numbers.

What to do Next

  • Programming Languages - Find your preferred programming language here and learn how to write your own code with Phidgets!
  • Phidget Programming Basics - Once you have set up Phidgets to work with your programming environment, we recommend you read our page on to learn the fundamentals of programming with Phidgets.


Product Specifications

Sensor Properties
Sensor Type Input (Slider)
Controlled By VoltageRatio Input
Sensor Output Type Ratiometric
Linear Travel (Electrical) 60 mm
Electrical Properties
Current Consumption Max 150 μA
Output Impedance 10 kΩ
Physical Properties
Operating Temperature Min -25 °C
Operating Temperature Max 70 °C
Customs Information
Canadian HS Export Code 8473.30.00
American HTS Import Code 8473.30.51.00
Country of Origin CN (China)

Documents

Product History

Date Board Revision Device Version Comment
June 2002 0N/A Product Release 45mm model
September 20030N/AChanged to 60mm slider
August 20040N/AAnalog input connector changed from stereo jack to 3-pin Molex
December 20081N/ASmoother slider used, smaller board

This device doesn't have an API of its own. It is controlled by opening a VoltageRatioInput channel on the Phidget that it's connected to. For a list of compatible Phidgets with VoltageRatio Inputs, see the Connection & Compatibility tab.

You can find details for the VoltageRatioInput API on the API tab for the Phidget that this sensor connects to.

Code Samples



Example Options


Downloads

				Make your selections to display sample code.
					

Have a look at our potentiometers:

Product Sensor Properties
Part Number Price Sensor Type Controlled By Linear Travel (Electrical)
3579_0
Linear Potentiometer - 75mm
$65.00 Input (Linear) VoltageRatio Input 75 mm
3580_0
Linear Potentiometer - 100mm
$75.00 Input (Linear) VoltageRatio Input 100 mm
3581_0
Linear Potentiometer - 200mm
$95.00 Input (Linear) VoltageRatio Input 200 mm
3582_0
Linear Potentiometer - 300mm
$120.00 Input (Linear) VoltageRatio Input 300 mm
POT2000_0
Slider 30
$9.00 Input (Slider) VoltageRatio Input
POT2001_0
Slider 60
$11.00 Input (Slider) VoltageRatio Input
POT2002_0
Slider 100
$14.00 Input (Slider) VoltageRatio Input