==Product History==
==Product History==


The 1063 - PhidgetStepper Bipolar was succeeded by the [{{SERVER}}/products.php?product_id=1067 1067 - PhidgetStepper HC]. The 1067 can run the steppers faster and comes with a number of built-in safety and protection features.
The 1063 - PhidgetStepper Bipolar was succeeded by the [{{SERVER}}/products.php?product_id=1067 1067 - PhidgetStepper HC]. The 1067 has the following changes:
* Increased maximum velocity and acceleration, allowing you to drive your stepper motor even faster
* Increased available motor current for larger motors
* Added safety features such as power isolation and a fuse for surge protection
* Microstepping at all speeds for smoother acceleration
* Removed motor current sensing
* Removed digital inputs
 


{{UGhist}}
{{UGhist}}

Revision as of 18:29, 2 April 2014

1063.jpg
Go to this device's product page


Getting Started

Checking the Contents

You should have received:

  • A PhidgetStepperBipolar 1-Motor Controller Board
  • A Mini-USB Cable

In order to test your new Phidget you will also need:

  • A 9 to 30V DC Power Supply (If you're using the barrel jack, make sure your power supply is center positive polarity)
  • A bipolar stepper motor
  • A length of wire

Connecting the Pieces

  1. Connect the motor to the PhidgetStepper board. If you are having difficulty connecting your motor, refer to the technical section.
  2. Connect the power supply to the board using the barrel connector.
  3. Power supplies with higher current (more than 2.5 Amps) should be wired directly to the terminal block.
  4. Connect one end of the piece of wire to digital input port 0 and the other end to the ground connector.
  5. Connect the PhidgetStepper board to your PC using the USB cable.

1063 1 Connecting The Hardware.jpg

Testing Using Windows 2000 / XP / Vista / 7

Make sure you have the current version of the Phidget library installed on your PC. If you don't, follow these steps:

  1. Go to the Quick Downloads section on the Windows page
  2. Download and run the Phidget21 Installer (32-bit, or 64-bit, depending on your system)
  3. You should see the Ph.jpg icon on the right hand corner of the Task Bar.

Running Phidgets Sample Program

Double clicking on the Ph.jpg icon loads the Phidget Control Panel; we will use this program to ensure that your new Phidget works properly.

The source code for the Stepper-full sample program can be found in the quick downloads section on the C# Language Page. If you'd like to see examples in other languages, you can visit our Languages page.

Updating Device Firmware

If an entry in this list is red, it means the firmware for that device is out of date. Double click on the entry to be given the option of updating the firmware. If you choose not to update the firmware, you can still run the example for that device after refusing.

Double Click on the Ph.jpg icon to activate the Phidget Control Panel and make sure that Phidget Bipolar Stepper Controller 1-Motor is properly attached to your PC.

1063 1 Control Panel Screen.jpg
  1. Double Click on Phidget Bipolar Stepper Controller 1-Motor in the Phidget Control Panel to bring up Stepper-full and check that the box labelled Attached contains the word True.
  2. Check the Engaged box to power up the motor.
  3. Move the Target Position slider to the right or the left. The target motor position will be displayed in the Position Target box and the motor will start turning until the Actual position is the same as the target.
  4. Use the Velocity Limit slider to set the maximum velocity. The motor will accelerate until the Actual velocity is equal to the Velocity Limit. Keep in mind that the maximum value on this slider is not actually the maximum velocity. See the API for more information.
  5. Use the Acceleration slider to increase or decrease the acceleration.
  6. Use the Current Limit slider to modify the current going through the motor and affect torque.
  7. When the motor has reached the position target, a tick mark will appear in the Stopped box.
  8. When the motor is stopped, you can set the current physical position of the motor to a certain value by using the Current Position slider. This is useful for zeroing the motor to a certain physical position.
  9. To test the Digital input, connect a wire between the digital input port 0 and the ground connector. The check mark in the Input 0 box should appear
1063 1 Stepper screen.jpg

Testing Using Mac OS X

  1. Go to the Quick Downloads section on the Mac OS X page
  2. Download and run the Phidget OS X Installer
  3. Click on System Preferences >> Phidgets (under Other) to activate the Preference Pane
  4. Make sure that the Phidget Bipolar Stepper Controller 1-Motor is properly attached.
  5. Double Click on Phidget Bipolar Stepper Controller 1-Motor in the Phidget Preference Pane to bring up the Stepper-full Sample program. This program will function in a similar way as the Windows version.

Using Linux

For a step-by-step guide on getting Phidgets running on Linux, check the Linux page.

Using Windows Mobile / CE 5.0 / CE 6.0

Template:UGce

Technical Details

How does the 1063 control Stepper Motors?

The 1063 can be used to control 4, 6, or 8 wire bipolar stepper motors.

The PhidgetStepper Bipolar is most effective when used with stepper motors designed to be driven with a chopper drive stepper controller. These motors are often large, with a rectangular industrial appearance. The specifications of these motors are often confusing and may seem contradictory. Our users are often confused attempting to relate the specifications of their motor to the capabilities of the 1063. If you are in doubt if your motor will work with the 1063, call us.

When the steppers are first engaged from software, the stepper motor likely will not be at the same state as the default output state of the controller. This will cause the stepper to ‘snap’ to the position asserted by the controller - potentially moving by 2 full steps.

At low speeds, less than 1024 1/16th steps per second, the 1063 uses a microstepping scheme to allow precise control of the current to each coil, and therefore the position of the stepper. It’s important to note that many steppers are not designed to be microstepped precisely, and will not accurately produce the expected angle.

At higher speeds, the 1063 switches to a full stepping mode. The 1063 will automatically switch back to microstepping when approaching the target position.

To avoid the use of floating point in the APIs, the position, velocity and acceleration parameters are expressed in microsteps (1/16th steps), instead of full steps. If your application wants to move the motor by 1 full step, you change the position by 16.

Open and Closed Loop Control

Because stepper motors do not have the inherent ability to sense their actual shaft position, they are considered open loop systems.

This means that the value contained in the current position property is merely a count of the number of steps that have occurred towards the target value; it can not be relied upon as a measure of the actual shaft angle, as external forces may also be affecting the motor.

There are several ways of overcoming this drawback. The simplest is to allow the motor load to depress a limit switch located at a known position. This can be used to fire an event in software to recalibrate the shaft position values. A more elegant solution might involve the mounting of an optical encoder on the shaft and the development of a control system.

How to Connect your Stepper to the 1063

Bipolar Steppers motors are available in 4, 6 or 8 wire configurations. Driving a motor in the Bipolar Configuration produces maximum torque. The word Bipolar means that the controlling electronics have to be able to produce a current flow in either direction in each coil, to produce magnetic fields in opposite directions.

4 Wire Stepper Motors

A 4 wire Stepper motor can only be controlled as a bipolar. There are two coils, with the ends of each coil brought out. By applying current to the two coils in sequence, and changing the direction of current flow, the motor can be made to rotate.

Determining how to connect a 4 wire stepper to the 1063 can be done by following this procedure. Suppose we have four wires: red, green, yellow and blue.

Start by measuring the resistance between all the wires. Below is a sample table of resistance data, in ohms. This table contains example values, your readings may be different but should still produce a similar pattern.

1063 1 Motor Types 4wire.jpg
Wire Color Green Blue Yellow Red
Green 30
Blue
Yellow 30
Red


Looking at the table, you see that there are two pairs of wires (Green-Blue, and Yellow-Red), with roughly the same resistance measured between the wires in each pair. Pick one of the four wires and wire it to the A terminal. The other wire in this pair is connected to the B terminal. At random, wire the other pair to C and D. The motor will turn in clockwise or counter-clockwise rotation. Swapping the A and B wires or the C and D wires will change whether the motor considers “forward” to mean clockwise or counter-clockwise rotation (Remember, steppers can be run in forward or reverse by choosing a target position greater than or less than the current position).

6 Wire Stepper Motors

In a 6 – wire bipolar motor, there is two + wires, one for each coil, which are the center taps for each coil. You will need to isolate which are the center tap wires and the corresponding wires for their coil.

These center taps are left unconnected to operate as a bipolar. Let’s assume our six wire stepper motor wires are colored as follows: red, green, blue, white, purple, and yellow.

We measure the resistance between all wires and are presented with the following values in ohms (these are simply example values):


1062 1 Motor Types 6wire.jpg


Wire Color Red White Yellow Purple Green Blue
Red 10 10
White 10 10
Yellow 20
Purple
Green 20
Blue

Looking at our table, we can see our pattern. The red wire has the same resistance to the green and blue wires. The white wire has the same resistance to the yellow and purple wire. Red, green, and blue are for one pole, and white, yellow, and purple are the other pole. The red and white wires are the center of their coils. Leave the red/white wires unconnected, and follow the instructions for connecting a 4-Wire Bipolar Motor as described earlier in this section.

There are in fact two valid combinations, one that will produce a clockwise rotation in the stepper motor for increasing position and one that will produce counter-clockwise rotation. Swapping the A and B wires or the C and D wires will change whether the motor considers “forward” to mean clockwise or counter-clockwise rotation.

8 Wire Stepper Motors

8 Wire Motors are very difficult to wire up if you do not have a schematic showing how the wires are connected to the internal coils. Only follow these instructions if you are really desperate.

In an 8 wire motor, the coils are split, and we have to reconnect the coils, to reduce them to a 4 wire. Assume our eight wire stepper motor wires are colored as follows: red, yellow, purple, orange, blue, green, brown, and white. In an 8-wire stepper motor, these wires would be part of 4 coils, 2 wires per coil. We need to determine the cable pairings.

We measure the resistance between each wire and are presented with the following values in ohms (these are simply example values):


1062 1 Motor Types 8wire.jpg
Wire Color Orange Red Yellow Purple Blue Green Brown White
Orange 1
Red 1
Yellow 1
Purple 1
Blue
Green
Brown
White


This table tells us which wires are parts of a coil. From the table we can tell that red/green, yellow/brown, purple/white, and orange/blue are the coils. We are now left with the following situation; we need to determine the proper orientation of the wires to determine our connections. Of each pair, one of the wires will be assigned to A, B, C, or D, and the other wire will be connected to another pair. The number of combinations to be tried to see if they produce rotation is large, but can be reduced to a maximum of 96 possibilities by following these steps:

  1. Choose one wire from a pair to connect to A. (2 possibilities)
  2. Choose one wire of the other pairs (6 possibilities) and connect to B. The other wire from this pair is connected to the wire from Step 1 not connected to A.
  3. Choose one wire from the two remaining pairs (4 possibilities) and connect to C.
  4. Choose one wire from the remaining pair (2 possibilities) and connect to the wire from Step 3 not connected to C. The remaining wire from this pair is connected to D.
  5. After trying each permutation, engage the motor from software and try to rotate it. Do not connect the pairs to anything - as if you were using a 6-wire stepper in bipolar mode.

If you attempt to use this algorithm, build a table of permutations beforehand and proceed in a systematic way.

There are a total of 96 wiring combinations, of which there are 2 valid combinations where one will cause a clockwise motor rotation and the other will cause a counter-clockwise rotation.

If you are not using a Phidget stepper, we suggest consulting any manuals or data sheets that are associated with your particular motor in order to determine the proper wiring for your motor.

Choosing a Power Supply Voltage

When looking at a stepper motor's specifications, you may come across a "Rated Voltage" value. This value is usually equal to the rated current multiplied by the resistance of the coils of the motor, making it somewhat of a redundant specification. As mentioned earlier, you can increase your controller's supply voltage in order to allow the motor to reach higher speeds at a lower current (because high current causes high inductance which puts a hard limit on how much speed and torque a motor can produce). The motor will also produce more heat as you increase the supply voltage, so it's a good idea to choose a supply voltage based on the performance you need for the motor. Some motors will have a "Recommended Voltage" for a particular controller, which is the amount of voltage needed to reach the optimal speed and torque of the motor with minimal heating.

For more information about how supply voltage affects your motor's maximum speed and torque, check the Stepper Motor Primer.

Setting Current Limit

The 1063 allows the current applied to the motor to be programmatically set. This is important - if the current limit is set too high, the motor’s internal resistance will cause the sine-wave approximations used to implement microstepping to clip at the maximum current possible, given your motor/supply voltage. This clipping will cause rough operation, or prevent the motor from turning. If the limit is set too low, the motor may not be able to handle it’s load, by missing steps, or not turning at all at high accelerations.

1063 1 Current Limiting.jpg

How to determine CurrentLimit

  • Disconnect one coil from the Phidget and make sure your power supply is set at the voltage you will use in your application.
  • The CurrentLimit has to be less than the current limit of your motor, so start CurrentLimit at a small value.
  • Using our example, change the position until you find a maximum current.
  • Move up the current limit until the current feedback is not increasing.

This is your current limit. If you do not need so much torque, you can reduce the current limit to save power and reduce heating. If you need more current than the 1063 is specified to provide, you'll need to add some form of heat dissipation to the driver chip (A3979), in the form of a heatsink, air circulation, or both. The only problem with artificially increasing this limit through cooling is that you have no way of knowing how much further you can push the controller without some sort of temperature monitoring.

For more information about setting the current limit, check the Stepper Motor Primer.

Continuous Rotation

A stepper motor can be caused to rotate continuously by simply setting the motor position property to an extremely large number of steps. The valid range of values for the motor position property is large enough to be able to cause the motor to continuously turn at maximum velocity for 194 days.

Saving Power

Holding torque is the amount of torque required to rotate the motor ‘against it’s will’ when the full rated current is flowing through the coils. If current consumption / heating is a problem, and full holding torque is not required, the Current Limit can be decreased in software when the motor is not moving. Holding torque will decrease linearly with the Current Limit.

There is also a small resistance to movement within the motor even when there is no current, called Detent Torque. This may be sufficient to prevent rotation in your application, particularly if the stepper has a gearbox on it.

If the motor is not supporting a load or is not required to maintain a specific angle, it is recommended to set the Enable property to false. This will allow the motor shaft to rotate freely, but the present angle may be lost if forces on the motor-shaft are greater than can be resisted by the detent torque of the unpowered motor.

High Precision Applications

Stepper motor precision is limited by the manufacturing process used to build them. Errors in the rotor and coils will cause some degree of inaccuracy. In our experience, inexpensive stepper motors will often have positioning errors approaching a half-step. Gearing a stepper motor down with a gearbox will reduce this error proportional to the reduction ratio of the gearbox.

Synchronization of Multiple Motors

Many applications call for several steppers motors operating in unison - for example, operating a CNC table, or a robot arm. Highly precise synchronization of steppers using the PhidgetStepper is not possible, as the sequencing will be affected by the real-time performance of your operating system. Each stepper is controlled as a independent unit, so there is no way of arranging for a particular action to happen to all motors at the same time. Typical jitter can be 10-30mS.

Compatibility Guidelines

When looking for a motor that will be compatible with the 1063, check the motor's data sheet and make sure it meets the following specifications.

  • Bipolar motor - While the 1063 can control some six-wire unipolar motors, we recommend you look for bipolar stepper motors.
  • 4, 6, or 8-wire motor - A 5-wire motor cannot be used with the 1063, because the coils of the motor are connected internally.
  • Rated/Recommended Voltage - If the motor comes with a rated or recommended voltage, it should be no more than 30 volts, and you should use a power supply that can output that voltage.
  • Rated Current - The motor should be rated for a maximum of 1.5A per coil.

Troubleshooting

If your stepper motor is not behaving correctly, you can use a multimeter to determine whether it is the controller or the motor that is at fault.

Disconnect the motor and set the current limit to 0. Set the target position to 7 and measure the voltage difference between the A and B terminals it should be either -12, or +12V assuming you are using a 12V power supply (just depending on which terminal you have the positive multimeter lead connected to). Then set the target position to 8, the voltage should drop to 0, and it will go to the opposite at 9 (-12 or +12). This pattern will repeat for 39,40,41 and 71,72,73 and 103,104,105 etc... in increments of 32. If this is behaving as expected then the problem is probably with how you have connected your motor, or your code.

Further Reading

For more information about the digital inputs on the 1063, check the Digital Input Primer.

For more information about stepper motors, check the Stepper Motor and Controller Primer.

API

Template:UGapih

Functions

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Events

Template:UGapi

Template:UGapi

Template:UGapi

Template:UGapi

Product History

The 1063 - PhidgetStepper Bipolar was succeeded by the 1067 - PhidgetStepper HC. The 1067 has the following changes:

  • Increased maximum velocity and acceleration, allowing you to drive your stepper motor even faster
  • Increased available motor current for larger motors
  • Added safety features such as power isolation and a fuse for surge protection
  • Microstepping at all speeds for smoother acceleration
  • Removed motor current sensing
  • Removed digital inputs


Template:UGhist Template:UGrow2 Template:UGrow2 Template:UGrow2