Relative Humidity Sensor HM1500LF

ID: 3130_0

This humidity sensor can measure the relative humidity in the environment from 10% to 95% RH. Connects to a Voltage Input.

Discontinued

The 1130 is a dedicated humidity transducer designed for applications where a reliable and accurate measurement is needed.


Product Features

  • Small size product
  • Product free from Lead, Cr(6+), Cd and Hg
  • Humidity calibrated within ±2% @55%RH
  • Ratiometric to voltage supply
  • Patented solid polymer structure
  • High reliability and long term stability
  • Not affected by water immersion
  • Very low temperature dependence
  • Instantaneous de-saturation after long periods in saturation phase
  • Part could be washed with distilled water

Product Specifications

Sensor Properties
Controlled By VoltageRatio Input
Sensor Type Humidity (Ambient)
Sensor Output Type Ratiometric
Humidity Sensor
Humidity Min 10 %RH
Humidity Max 95 %RH
Humidity Resolution 0.4 %RH
Humidity Error (At 55%RH) ± 2 %RH
Humidity Error Max ± 5 %RH
Humidity Response Time Max 10 s
Electrical Properties
Supply Voltage Min 4.8 V DC
Supply Voltage Max 5 V DC
Current Consumption Max 1.4 mA
Output Impedance 70 Ω
Physical Properties
Operating Temperature Min -40 °C
Operating Temperature Max 60 °C
Cable Length 240 mm
Customs Information
Canadian HS Export Code 9025.80.00
American HTS Import Code 9025.80.10.00
Country of Origin FR (France)

The easiest way to connect the sensor is to use a 3002 - Phidget Cable 60cm or a 3004 - Phidget Cable 350cm ; cut the Phidget cable to the desired length and solder the load cell wires to the Phidget cable as follows:

3130 - Sensor Phidget Cable Function
Blue Red Supply Voltage
White Black Ground
Yellow White Humidity Output Voltage
FUNCTIONAL

Then, connect the load cell to any device with an Analog Input.

Documents

Formula


The Formula to translate SensorValue into Relative Humidity is:

RH (%) = (SensorValue * 0.1906) - 40.2