===Getting Started===
==Getting Started==
{{UGIntro|ADP1000}}
{{UGIntro|ADP1000}}
* [{{SERVER}}/products.php?product_id=ADP1000 ADP1000 - pH Phidget]
* [{{SERVER}}/products.php?product_id=ADP1000 ADP1000 - pH Phidget]
* {{VINTHub}}
* {{VINTHub}}
* [{{SERVER}}/?view=comparetable&rel=Phidget%20Cables Phidget cable]
* {{CT|PhidgetCable|Phidget cable}}
* USB cable and computer
* USB cable and computer
*[{{SERVER}}/?view=comparetable&rel=Probes compatible pH/ORP probe]
* {{CT|pHORPProbe|compatible pH/ORP probe}}




Next, you will need to connect the pieces:
Next, you will need to connect the pieces:
 
[[Image:ADP1000-functional.jpg|500px|link=|right]]
[[Image:ADP1000-functional.jpg|500px|link=]]
 
# Connect the ADP1000 to the VINT Hub using the Phidget cable.
# Connect the ADP1000 to the VINT Hub using the Phidget cable.
# Connect the VINT Hub to your computer with a USB cable.
# Connect the VINT Hub to your computer with a USB cable.
Line 28: Line 28:
*{{UGVoltageRangeDescription}}
*{{UGVoltageRangeDescription}}


{{ugAddressingInformation}}
{{ugUsingYourOwnProgram|ADP1000}}


==Technical Section==
==Technical Section==
Line 71: Line 74:
<br clear="all">
<br clear="all">


As you can see from the examples above, temperature has a greater impact on solutions that have a pH further away from 7. If you want to monitor the temperature of your solution, you can use a thermocouple. Check out our [{{SERVER}}/?view=comparetable&rel=Thermocouple%20Interfaces thermocouple interfaces] for more information. For more information about how to set a ''Correction Temperature'', view the {{Phidget22API}}.
As you can see from the examples above, temperature has a greater impact on solutions that have a pH further away from 7. If you want to monitor the temperature of your solution, you can use a thermocouple. Check out our {{CT|TCInterface|thermocouple interfaces}} for more information. For more information about how to set a ''Correction Temperature'', view the {{Phidget22API}}.


===Measuring ORP===
===Measuring ORP===

Revision as of 16:27, 17 October 2019


Getting Started

Welcome to the ADP1000 user guide! In order to get started, make sure you have the following hardware on hand:


Next, you will need to connect the pieces:

ADP1000-functional.jpg
  1. Connect the ADP1000 to the VINT Hub using the Phidget cable.
  2. Connect the VINT Hub to your computer with a USB cable.
  3. Connect a pH or ORP probe to the ADP1000.


Now that you have everything together, let's start using the ADP1000!.

Using the ADP1000

Phidget Control Panel

In order to demonstrate the functionality of the ADP1000, the Phidget Control Panel running on a Windows machine will be used.


The Phidget Control Panel is available for use on both macOS and Windows machines.

Windows

To open the Phidget Control Panel on Windows, find the Ph.jpg icon in the taskbar. If it is not there, open up the start menu and search for Phidget Control Panel

Windows PhidgetTaskbar.PNG

macOS

To open the Phidget Control Panel on macOS, open Finder and navigate to the Phidget Control Panel in the Applications list. Double click on the Ph.jpg icon to bring up the Phidget Control Panel.


For more information, take a look at the getting started guide for your operating system:


Linux users can follow the getting started with Linux guide and continue reading here for more information about the ADP1000.

First Look

After plugging the ADP1000 into your computer and opening the Phidget Control Panel, you will see something like this:

ADP1000 Panel.jpg


The Phidget Control Panel will list all connected Phidgets and associated objects, as well as the following information:

  • Serial number: allows you to differentiate between similar Phidgets.
  • Channel: allows you to differentiate between similar objects on a Phidget.
  • Version number: corresponds to the firmware version your Phidget is running. If your Phidget is listed in red, your firmware is out of date. Update the firmware by double-clicking the entry.


The Phidget Control Panel can also be used to test your device. Double-clicking on an object will open an example.

PH Sensor

Double-click on the PH Sensor object in order to run the example:

ADP1000 PHSensor Example.jpg


General information about the selected object will be displayed at the top of the window. You can also experiment with the following functionality:

  • Modify the change trigger and/or data interval value by dragging the sliders. For more information on these settings, see the data interval/change trigger page.
  • Set the temperature of your solution for more accurate results. See the technical section for more details.

Voltage Input

Double-click on the Voltage Input object in order to run the example:

ADP1000 VoltageInput Example.jpg


General information about the selected object will be displayed at the top of the window. You can also experiment with the following functionality:

  • Modify the change trigger and/or data interval value by dragging the sliders. For more information on these settings, see the data interval/change trigger page.
  • Use the Voltage Range drop-down menu to select an appropriate range for the voltage you are trying to measure.

Finding The Addressing Information

Before you can access the device in your own code, and from our examples, you'll need to take note of the addressing parameters for your Phidget. These will indicate how the Phidget is physically connected to your application. For simplicity, these parameters can be found by clicking the button at the top of the Control Panel example for that Phidget.

The locate Phidget button is found in the device information box

In the Addressing Information window, the section above the line displays information you will need to connect to your Phidget from any application. In particular, note the Channel Class field as this will be the API you will need to use with your Phidget, and the type of example you should use to get started with it. The section below the line provides information about the network the Phidget is connected on if it is attached remotely. Keep track of these parameters moving forward, as you will need them once you start running our examples or your own code.

All the information you need to address your Phidget

Using Your Own Program

You are now ready to start writing your own code for the device. The best way to do that is to start from our Code Samples.

Select your programming language of choice from the drop-down list to get an example for your device. You can use the options provided to further customize the example to best suit your needs.

Code Sample Choose Language.png


Once you have your example, you will need to follow the instructions on the page for your programming language to get it running. To find these instructions, select your programming language from the Programming Languages page.

Technical Section

Measuring pH

The ADP1000 automatically converts raw voltage (from the pH probe) into an extremely accurate pH reading. For even more accuracy, you can set a Correction Temperature. The Correction Temperature simply corresponds to the temperature of the solution you are measuring (in °C). Here are a few examples to give you a better idea of how temperature affects the output voltage of a pH probe:

Temperature (°C) pH Voltage (V)
0 8 2.76
25 8 2.78
100 8 2.85


Temperature (°C) pH Voltage (V)
0 2 1.21
25 2 1.095
100 2 0.74


As you can see from the examples above, temperature has a greater impact on solutions that have a pH further away from 7. If you want to monitor the temperature of your solution, you can use a thermocouple. Check out our thermocouple interfaces for more information. For more information about how to set a Correction Temperature, view the Phidget22 API.

Measuring ORP

For ORP probes, the raw voltage value is equivalent to the actual oxidation reduction potential in Volts.

Current Consumption

The amount of current this device consumes is dependant on the data interval and input mode you select. The more frequent the data updates, the higher the current consumption will be.

ADP1000 Current.jpg

Further Reading

For more information on pH and ORP probes, check the PH/ORP Sensor Primer.

What to do Next

  • Programming Languages - Find your preferred programming language here and learn how to write your own code with Phidgets!
  • Phidget Programming Basics - Once you have set up Phidgets to work with your programming environment, we recommend you read our page on to learn the fundamentals of programming with Phidgets.