Replaced by the 3109_0 - TPK-01G Bead Probe K-type Thermocouple (-50°C to +450°C)
The 3110 - K-Type thermocouple can measure temperatures between -50°C to +785°C with a ±0.75°C accuracy.
The thermocouple wire is insulated with fiberglass.
Sensor Properties | |
---|---|
Controlled By | Thermocouple Interface |
Sensor Type | Thermocouple |
Temperature Sensor | |
Thermocouple Type | K |
Probe Type | Bead |
Ambient Temperature Min | -50 °C |
Ambient Temperature Max | 785 °C |
Ambient Temperature Error Max | ± 0.75 °C |
Physical Properties | |
Connector Type | 6mm Stripped Leads |
Cable Length | 1 m |
Cable Gauge | 24 AWG |
Insulation Material | Fiberglass |
Probe Material | chromel-alumel |
Customs Information | |
Canadian HS Export Code | 9025.19.00 |
American HTS Import Code | 9025.19.80.85 |
Country of Origin | TW (Taiwan) |
The Thermocouple is designed to plug into one of the terminal blocks on the:
Note: When you connect your thermocouple, you'll need to determine if you have the polarity correct. Since both leads look identical, you need to use trial and error. Try heating the probe of the thermocouple and if the temperature reading goes down or behaves erratically, you probably have the leads backward.