TPK-03 Immersion Probe K-type Thermocouple (-50 to +700°C)

ID: 3108_2

This K-Type thermocouple measures temperatures from -50°C to 700°C and connects to a Phidgets thermocouple board.

Discontinued

Replaced by the TMP4106 - K-Type Probe Thermocouple 11cm

The 3108 - K-Type thermocouple can take continuous temperature readings between -50°C to +700°C with a ±0.75°C accuracy. The 3108 can also take a instant, single temperature reading between -100°C to +900°C.

It is typically used to take the temperature of liquids and gels.


For more information on thermocouples, visit the Thermocouple Guide.

Connection

This thermocouple connects to a thermocouple interface. See the Connection & Compatibility tab for details.

Product Specifications

Sensor Properties
Sensor Type Thermocouple
Controlled By Thermocouple Interface
Temperature Sensor
Thermocouple Type K
Probe Type Immersion
Ambient Temperature Min -50 °C
Ambient Temperature Max 700 °C
Ambient Temperature Min (Momentary) -100 °C
Ambient Temperature Max (Momentary) 900 °C
Ambient Temperature Error Max ± 0.75 °C
Physical Properties
Connector Type Miniature Male Connector
Cable Length 850 mm
Probe Diameter 3.2 mm
Cable Gauge 28 AWG
Insulation Material PE Plastic
Probe Material K/316 Stainless Steel
Handle Material Engineering Plastic
Customs Information
Canadian HS Export Code 9025.19.00
American HTS Import Code 9025.19.80.85
Country of Origin TW (Taiwan)

Thermocouple Interfaces

This K-type thermocouple can be read by connecting it to any of the thermocouple interfaces in the list below.

Note: On the 1051 or TMP1100, connect the white thermocouple wire to the (-) terminal block and the red wire to the (+) terminal block.
On the 1048 or TMP1101, connect the white wire to G and the red wire to input terminal block (numbered 0 to 3).

Function 3108
Thermocouple
Thermocouple
Interface
+ Red + / #
- White - / G
Functional

Thermocouple Accessories

Thermocouples cannot easily be soldered, since adding an additional metal junction will throw off the readings. The following products will help connect or extend thermocouple wires.

Check out our thermocouples:

Product Temperature Sensor
Part Number Price Thermocouple Type Ambient Temperature Min Ambient Temperature Max Ambient Temperature Error Max
TMP4103_0
K-Type Teflon Bead Probe Thermocouple (-40°C to +200°C)
$5.00 K -40 °C 200 °C ± 0.75 °C
TMP4104_0
K-Type Fiberglass Bead Probe Thermocouple
$10.00 K -40 °C 400 °C ± 0.75 °C
TMP4106_0
K-Type Probe Thermocouple 11cm
$16.00 K -40 °C 400 °C 3.3 °C
TMP4107_0
K-Type Probe Thermocouple 20cm
$16.00 K -40 °C 400 °C 3.3 °C
TMP4111_0
K-Type Probe Thermocouple 30cm
$20.00 K -40 °C 400 °C 3.3 °C