Products for USB Sensing and Control
1018_2 - PhidgetInterfaceKit 8/8/8
Quantity Price
1$80.00
5$76.80
10$74.40
25$72.00
50$68.00
In Stock
Qty: 1000+
ROHS

Product Features


The Phidgets workhorse. Connect analog sensors, control switches, and check on push-buttons. One board handles up to 24 devices.
Product Description

Analog Inputs

The Analog Inputs are used to measure continuous quantities, such as temperature, humidity, position, pressure, etc. Phidgets offers a wide variety of sensors that can be plugged directly into the board using the cable included with the sensor. For more information about these inputs and their connectors, have a look at the Analog Input Primer.

Sampling rates can be set at 1ms, 2ms, 4ms, 8ms and multiple of 8ms up to 1000ms.

Digital Inputs

The Digital Inputs have a Digital Input Hardware Filter to eliminate false triggering from electrical noise. They can be used to convey the state of devices such as push buttons, limit switches, relays, and logic levels.

Digital Outputs

The Digital Outputs can be used to drive LEDs, solid state relays (such as the 3052 SSR Relay Board), transistors; in fact, anything that will accept a CMOS signal.



Product Specifications

Board

API Object NameInterfaceKit
USB Voltage Min4.6 V DC
USB Voltage Max5.5 V DC
Current Consumption Min13 mA
Current Consumption Max500 mA
Available External Current487 mA
Recommended Wire Size16 - 26 AWG
USB SpeedFull Speed
Operating Temperature Min0 °C
Operating Temperature Max70 °C

Analog Inputs

Number of Analog Inputs8
Analog Input Resolution10 bit
Input Impedance900 kΩ
Analog Input Voltage Min0 V DC
Analog Input Voltage Max5 V DC
5V Reference Error Max0.5 %
Analog Input Update Rate Min1 samples/s
Analog Input Update Rate Max (4 Channels)1000 samples/s
Analog Input Update Rate Max (8 Channels)500 samples/s
Analog Input Update Rate Max (WebService)62.5 samples/s

Digital Inputs

Number of Digital Inputs8
Pull-up Resistance15 kΩ
Low Voltage Max (True)900 mV DC
High Voltage Min (False)4.2 V DC
Low Voltage Trigger Length Min4 ms
High Voltage Trigger Length Min15 ms
Digital Input Voltage Max± 15 V DC
Digital Input Update Rate125 samples/s

Digital Outputs

Number of Digital Outputs8
Series Resistance300 Ω
Digital Output Current Max16 mA
Digital Output Voltage Min0 V DC
Digital Output Voltage Max5 V DC